Axens Blog

How to Remove Mercury from Extracted Natural Gas?

Written by Axens | Jul 14, 2020 5:20:00 PM

Mercury, a Natural Substance in the Natural Gas Composition

 

Mercury is a metal that occurs naturally and can exist in many different forms in the environment:

  •  Elemental Mercury (Hg0): in its
  •  pure form is liquid at ambient temperature and  can  evaporate and react to  form inorganic mercury compounds, falling back down on land or in the water.
  • Mercury compounds: they can be either organic or inorganic and formed from the reaction with other elements.

To prevent an increased release of mercury in the environment, concerted international actions have been taken such as the signature of the Minamata Convention on Mercury by over 130 parties in October 2013, taking effect on August 2017.

Mercury is naturally present in natural gas, and depending on the geological area, as per figure 1, will range from undetected level up to 300 microgram/Nm3 of gas.

 

Figure 1

 

What are the Main Reasons to Remove mercury (Hg) ?

 

The main reasons to remove Mercury (Hg0) from hydrocarbons are Health and Environmental related issues.

Elemental mercury is toxic through inhalation, skin exposure and ingestion. These different kinds of mercury exposure can induce neurologic diseases, cardiomyopathy, pulmonary and/or renal diseases.

 

Suitable personal protective equipment is required during maintenance work. For instance, the OSHA (Occupational Safety and Health Administration) sets an exposure limit for mercury up to 0.1 mg/m3 of air, which is currently enforced as an 8-hour time-weighted average.

 

In addition, mercury forms amalgams with some metallic alloys leading to corrosion issues. Indeed, mercury induces corrosion of aluminium-based cryogenic exchangers used for natural gas liquefaction. Mercury removal units are thus mandatory for LNG applications. The specification for LNG application is 10 nanogram/Nm3 as this corresponds to the analytical quantification limit of current analytical devices.

 

Mercury can also lead to catalyst poisoning and thus deactivation in oil refineries and petrochemical industry.

 

Mercury Removal

 

Mercury is present at traces level in natural gas and condensates and is dissolved respectively in the hydrocarbons gas phase or in the hydrocarbons liquid phase. It is important to highlight that mercury is mainly present under its elemental form (Hg0) in natural gas and associated condensates.

The safest and standard solution to remove mercury occurs in a fixed-bed reactor, and is based on an irreversible chemical reaction between elemental mercury and an active phase. The active phase contains sulfur that reacts selectively with elemental mercury leading to the most stable solid form of mercury ore called cinnabar (HgS). Indeed, the spent solid needs to handle a distillation under vacuum at very high temperature in order to recover the mercury from the solid.

 

This active phase can either be:

  • Elemental sulphur (S) like in activated carbons. Activated carbons were the historical solutions to remove mercury, as mercury removal units (MRU) were used to be located downstream of dryers.
  • Metal sulphide active phase, such as copper sulphide (MeS). Developed recently, they offer more capacity as compared with activated carbons.
Did you know?

Sulfur in either its elemental sulfur form (S) or under metal sulphide form (MeS) leads to the formation of solid-stable cinnabar (HgS) on the adsorbent as per the following reactions:

Elemental sulfur reaction: Hg0 + S → HgS

Metal sulphide reaction: Hg0 + 2 MeS → HgS + Me2S

 

In recent gas plant designs, mercury removal units are implemented as close as possible to the production wells in order to minimize mercury contamination in the effluents and along the natural gas processing chain, cf. Figure 2. This up-front position will minimize maintenance and operating expenses.

 

Figure 2

 

As a consequence, operating conditions are more drastic with high operating pressure and water-saturated streams which may also contain liquid hydrocarbons. In these operating conditions, the gas is at its water dew point: it implies frequent or permanent liquids entrainments (water and hydrocarbons) even if an efficient gas/liquid coalescer is implemented upstream of the mercury removal unit. Presence of liquids can have a detrimental impact on adsorbent integrity and/or performances depending on the selected solution.

 

Activated carbons cannot be used at this location as the active phase (elemental sulphur) is just deposited on the support and is easily leached by liquids entrainments. In addition, they are prone to capillary condensation of water and heavier hydrocarbons due to the presence of microporosity. Inorganic routes, however, including a metal sulphide as active phase ensure active phase stability under these operating conditions.

 

In the 90’s, solutions were made available in the market by the competition. They consist on a metal sulphide as active phase with only a binder to make the adsorbent shape. These adsorbents are called “bulk metal sulphides” and are not porous. Even if this kind of adsorbent contains a very high active phase concentration, several drawbacks can be mentioned:

  • Due to the absence of porosity in the adsorbent, only a few active sites of the external surface of the adsorbent are available to react with mercury,
  • Another consequence of the binder is a lack in mechanical properties especially in presence of free water, leading to cementing and pressure drops issues.

In upstream operating conditions, Axens’ Alumina supported metal sulphides allow to radically improve mercury removal performances as compared with the above-mentioned technologies.

 

Axens was a pioneer in the development of alumina-based adsorbent. Launched in the 70’s, this metal sulphide on porous optimized alumina carrier presents a very high mechanical resistance, thanks to:

  • The alumina carrier, and
  • The firm link between the active phase and the alumina carrier thanks to the manufacturing route.

The diffusion of the mercury contained in the gas to the active sites can be an issue. Indeed, free water can block the access of mercury to the active sites, leading to a broadening mass transfer zone and therefore a premature mercury breakthrough. This is why Axens, thanks to its wide experience in aluminas manufacturing, has optimized alumina carriers in order to favour the mercury diffusion to the active sites with both tailored adsorbent particles size and adsorbent porosity.

 

Axens’ AxTrap™ Mercury Series offer a complete portfolio of adsorbents for different level of Mercury contamination and gas conditions, for a wide range of applications: dry gas, wet gas (high operating pressure) and liquid phase operation. The adsorbents physical properties are optimized to minimize diffusion issues and maximize mercury trapping capacity. Once trapped, Mercury is then firmly bound within the product thanks to a proven manufacturing process and stringent mercury removal specifications can be reached.